Steps to a Successful Radon Measurement
What are Closed Building Conditions??
Initiate the request. We will need your name, contact information, reason for the test, property address, property details, and realtor information
1.
We will then schedule a time to access the property. If the test is part of a real estate transaction we will schedule access with the listing agent. Otherwise, we will schedule access with the home owner.
2.
The Radon Measuement technician will established that closed building conditions have been met including:
-
Windows have been closed for at least 12 hours prior to the start of the test
-
Temperature is set between 67-77 degrees
-
Fireplace flues are closed
3.
The technician will set up the Radon monitors in appropriate locations. Measures will be taken to ensure monitors were not disturbed and closed building conditions were maintained throughout the test.
4.
Arrangements will be made with the appropriate person for Radon monitor pick up. Typically, this should take place 48 hours after the monitor is set. If closed building conditions were not met at the time of monitor drop off the test may have to be extended, delaying the pick up day/time.
5.
The Technician arrives at the property to pick up monitors. The building is checked again for closed building conditions. The technician will also look for signs of tampering.
6.
The technician uploads all data including notes and floor plans. The report is assembled and reviewed. Payment is required before the report is released.
7.
WINDOWS & DOORS
Windows should be closed for 12 hours before the test begins. Doors should be kept closed as much as possible, though normal entry and exit is acceptable
Housekeeping
-
Whole house fans shall not be used.
-
Ceiling fans, portable dehumidifiers, and air filters should be not be used within 20 feet of a monitor.
-
Fireplaces shall not be used during the testing period and the flue damper should be kept closed.
-
Dryers, range hoods, and bath exhaust fans can be used in moderation.
Temperature
The building temperature should be between 67 and 77 degrees at the start of the test and remain at that temperature throughout the duration of the test.
Mitigation Systems
Existing Radon Mitigation Systems should remain on and functioning throughout the test.